Our super heated steam sterilizer was developed specifically for terminal treatment of solutions in closed flexible containers. It was developed primarily to overcome the temperature-pressure restrictions of the conventional steam sterilizer, so as to counteract the effects of the overpressure, which unavoidably forms inside containers when these are sterilized using conventional saturated-steam autoclaves.
Specifications
- Inner Chamber : SS 316
- Door : Hinged Door /Sliding door (Vertical/Horizontal)
- Mode of control : PLC/ SCADA
- Pressure switch : An automatic pressure switch adjustable type is provided to set the required pressure.
Applications
- Large volume parenterals in glass containers, rigid or semi-rigid plastic, flexible plastic.
- Injectable products in plastic ampoules, syringe ampoules.
- Solution in plastic metering containers, in cans with flip-off or threaded closures.
Features
- High powered centrifugal pump used for re-circulation of water in the system
- Single or double door with Sliding or Hinged door options to suit client specific requirements.
- Plate type heat exchanger for efficient heating and cooling of water.
- Special distribution plate arrangement for optimal water shower
- Water spray distribution headers fitted with nozzle suitably located to assure water uniform distribution on the product with consequent excellent temperature uniformity throughout the entire load.
- Installation is floor or pit mounted
- Optional automatic loading - unloading system
- Single or double door, semi-automatic hinged type or automatic sliding type
- Temperature & pressure monitoring inside the chamber
- PLC & HMI based control system with provision for SCADA connectivity.
- Range of alarms & safety devices for product, process & operator safety
- Strip chart or paperless recorders available